Issue
Rev. Phys. Appl. (Paris)
Volume 15, Number 5, mai 1980
Page(s) 977 - 983
DOI https://doi.org/10.1051/rphysap:01980001505097700
Rev. Phys. Appl. (Paris) 15, 977-983 (1980)
DOI: 10.1051/rphysap:01980001505097700

Analyse physique élémentaire de l'équation simplifiée du capteur plan à air en régime stationnaire

P. Rivet et Groupe Ramses

C.N.R.S. PIRDES, Laboratoire de Physique Corpusculaire, Collège de France, 75231 Paris Cedex 05, France


Abstract
A simple calculation made in the frame of approximations commonly used in the study of flat plate solar collectors and applied to the air collectors, allows to recover the usual formula giving the efficiency of the collector. The physical meaning of the parameters is explicitly exhibited. The conductivity of the absorbing surface is taken in account in the calculation. It has almost no part in the result. The temperature distribution of the fluid and of the absorbing surface in the flow direction are given.


Résumé
Un calcul relativement simple, effectué dans le cadre des approximations usuelles des capteurs solaires plans et appliqué au capteur à air, ou plus généralement à un capteur dont le fluide caloporteur s'écoule d'un mouvement uniforme au contact d'un absorbeur, permet de retrouver la formule classique donnant le rendement du capteur en explicitant la signification physique des paramètres qui interviennent dans cette formule. La conductivité de l'absorbeur est prise en compte dans le calcul et l'on s'aperçoit que son rôle est presque toujours négligeable. On donne enfin l'évolution des températures du fluide et de l'absorbeur le long du parcours du fluide.

PACS
4450 - Thermal properties of matter phenomenology.
8630S - Photothermal conversion.

Key words
solar absorber convertors -- flat plate solar air collector -- flat plate solar collectors -- efficiency -- conductivity -- absorbing surface -- temperature distribution -- flow direction -- air heaters