Numéro |
Rev. Phys. Appl. (Paris)
Volume 20, Numéro 10, octobre 1985
|
|
---|---|---|
Page(s) | 741 - 752 | |
DOI | https://doi.org/10.1051/rphysap:019850020010074100 |
DOI: 10.1051/rphysap:019850020010074100
Résonateur à quartz pour environnement sévère
R. DelaiteLaboratoire de Chronométrie, Electronique et Piézoélectricité, Ecole Nationale Supérieure de Mécanique et des Microtechniques, La Bouloie, Route de Gray, 25030 Besançon Cedex, France
Abstract
The effect of axial and radial accelerations on frequency of quartz crystal-resonator as a function of various holders are studied. The results lead to describe a particular structure showing a reduction of mechanical strains due to acceleration and external pressure variations. A prototype is manufactured. First results show a reduction of sensitivity coefficients in comparison to traditional resonators : a factor of ten for acceleration and a factor of ten to twenty for external pressure variations.
Résumé
L'influence d'accélérations axiale et radiale sur la fréquence de résonance d'un cristal de quartz présentant différents types de liaison avec l'environnement est examinée. Une situation limitant l'influence de l'accélération et des variations de la pression extérieure est décrite; une version prototype est réalisée. Les résultats obtenus font apparaître une diminution de la sensibilité accélérométrique d'un facteur 10 par rapport à celle des résonateurs traditionnels et d'un facteur 10 à 20 pour la sensibilité aux variations de la pression extérieure.
2860 - Piezoelectric and ferroelectric devices.
Key words
crystal resonators -- axial accelerations -- severe environments -- radial accelerations -- frequency -- quartz crystal resonator -- mechanical strain -- external pressure variations -- sensitivity coefficients