Détection de photoneutrons avec un scintillateur liquide chargé au gadolinium

H. Beil, R. Bergère et A. Veyssière

Service des Mesures Neutroniques Fondamentales, C.E.N., Saclay


Abstract
The essential characteristics of a large, gadolinium loaded (0.5 % in weight), liquid scintillator for neutron detection, used in photonuclear work at Saclay, are described. Efficiencies of the order of 85 % are obtainable thus making observations of photonuclear reactions of the type (γ, 3n) or (γ, 2n) possible. Reasonable agreement between theoretical and experimental time histories for neutron capture inside the detector exists. Total background is reduced to 6 x 10-3 count per 25 μs time gate.


Résumé
Un scintillateur liquide chargé au gadolinium (0,5 % en poids) et employé récemment à Saclay comme détecteur de photoneutrons est décrit. Des efficacités de détection de neutrons ε de l'ordre de 85 % peuvent être atteintes. Ceci a permis de séparer les interactions (γ, 3n) des interactions (γ, 2n) et (γ, n). Nous indiquons également la bonne concordance entre les résultats expérimentaux et théoriques pour les probabilités de capture des neutrons par Gd, dans la boule. Le bruit de fond total a été réduit à 6 x 10-3 coup par porte de 25 μs.

PACS
2940M - Scintillation detectors: scintillators and photomultipliers.
7420 - Particle and radiation detection and measurement.

Key words
gadolinium -- scintillation counters