Articles citing this article

The Citing articles tool gives a list of articles citing the current article.
The citing articles come from EDP Sciences database, as well as other publishers participating in CrossRef Cited-by Linking Program. You can set up your personal account to receive an email alert each time this article is cited by a new article (see the menu on the right-hand side of the abstract page).

Cited article:

This article has been cited by the following article(s):

Cadmium telluride and mercuric iodide gamma radiation detectors

R.C. Whited and M.M. Schieber
Nuclear Instruments and Methods 162 (1-3) 113 (1979)
DOI: 10.1016/0029-554X(79)90709-2
See this article

Solid-State Room-Temperature Energy-Dispersive X-Ray Detectors

Andrzej J. Dabrowski
Advances in X-ray Analysis 25 1 (1981)
DOI: 10.1154/S0376030800009460
See this article

Determination of trap parameters in electrodeposited CdTe by schottky barrier capacitance measurements

B.M. Basol and O.M. Stafsudd
Thin Solid Films 78 (3) 217 (1981)
DOI: 10.1016/0040-6090(89)90586-5
See this article

Advantages and limitations of n-type low resistivity cadmium telluride nuclear radiation detectors

A.J. Da̧browski, J. Iwańczyk, W.M. Szymczyk, et al.
Nuclear Instruments and Methods 150 (1) 25 (1978)
DOI: 10.1016/0029-554X(78)90452-4
See this article

Semiconductor X-Ray Detectors

Series in Sensors, Semiconductor X-Ray Detectors 20133231 349 (2013)
DOI: 10.1201/b16093-11
See this article

Performance Comparison of Standard CdTe and Hgl2 Detectors

C. Scharager, P. Siffert, A. Holtzer and M. Schieber
IEEE Transactions on Nuclear Science 27 (1) 276 (1980)
DOI: 10.1109/TNS.1980.4330839
See this article

Serious Degradation Characters of CdTe Nuclear Detector by Electron or Gamma Irradiations

Tadayoshi Shoji, Tsunemasa Taguchi, Yukio Hiratate and Yoshio Inuishi
IEEE Transactions on Nuclear Science 26 (1) 316 (1979)
DOI: 10.1109/TNS.1979.4329651
See this article

Current possibilities and limitations of cadmium telluride detectors

P. Siffert
Nuclear Instruments and Methods 150 (1) 1 (1978)
DOI: 10.1016/0029-554X(78)90450-0
See this article

Semiconductors for Room Temperature Nuclear Detector Applications

Makram Hage-Ali and Paul Siffert
Semiconductors and Semimetals, Semiconductors for Room Temperature Nuclear Detector Applications 43 291 (1995)
DOI: 10.1016/S0080-8784(08)62747-7
See this article

MIS-diode as a low-energy X- and γ-ray spectrometer

Anka A. Konova
Nuclear Instruments and Methods 160 (1) 115 (1979)
DOI: 10.1016/0029-554X(79)90171-X
See this article

Characteristics of MSM-type CdTe γ-ray detector fabricated from undoped p-type crystals

T. Shoji, T. Taguchi, K. Ohba and Y. Hiratate
Physica Status Solidi (a) 57 (2) 765 (1980)
DOI: 10.1002/pssa.2210570236
See this article

Capacitance of cadmium telluride Schottky diodes

B. Rabin, H. Tabatabai and P. Siffert
Physica Status Solidi (a) 49 (2) 577 (1978)
DOI: 10.1002/pssa.2210490220
See this article

Advances in X-Ray Analysis

Andrzej J. Dabrowski
Advances in X-Ray Analysis 1 (1982)
DOI: 10.1007/978-1-4613-9993-3_1
See this article