| Numéro |
Rev. Phys. Appl. (Paris)
Volume 12, Numéro 10, octobre 1977
|
|
|---|---|---|
| Page(s) | 1309 - 1314 | |
| DOI | https://doi.org/10.1051/rphysap:0197700120100130900 | |
Rev. Phys. Appl. (Paris) 12, 1309-1314 (1977)
DOI: 10.1051/rphysap:0197700120100130900
The Weizmann Institute of Science, Rehovot, Israël
2915B - Electrostatic accelerators.
7410 - Particle accelerators.
Key words
electrostatic accelerators -- Koffler accelerator -- terminal charge selector -- sputtering ion source -- chopper buncher -- acceptance performance
DOI: 10.1051/rphysap:0197700120100130900
The Koffler accelerator in Rehovot
G. GoldringThe Weizmann Institute of Science, Rehovot, Israël
Abstract
The new 14UD accelerator in Rehovot has been accepted on april 1st, 77. The acceptance performance is described, as well as some supplementary devices : the terminal charge selector, the sputtering ion source and the chopper-buncher.
Résumé
Le nouvel accélérateur 14UD à Réhovot a été réceptionné le 1.4.77. On décrit ses caractéristiques de fonctionnement ainsi que divers équipements supplémentaires, le sélecteur de charge au terminal, la source d'ions à sputtering et le hacheur-groupeur.
2915B - Electrostatic accelerators.
7410 - Particle accelerators.
Key words