Numéro
Rev. Phys. Appl. (Paris)
Volume 22, Numéro 5, mai 1987
Page(s) 359 - 366
DOI https://doi.org/10.1051/rphysap:01987002205035900
Rev. Phys. Appl. (Paris) 22, 359-366 (1987)
DOI: 10.1051/rphysap:01987002205035900

Expérimentation d'un ensemble machine à réluctance variable-convertisseur à extinction forcée - 150 kW - 500 tours/min - 200 Hz

R. Goyet1, C. Nasr1 et C. Glaize2

1  Laboratoire d'Electrotechnique (CNRS - UA 845), Bât. 214, Université Paris-Sud, 91405 Orsay, France
2  L.E.S.I.R. ENS de Cachan, 61, avenue du Président Wilson, 94230 Cachan, France


Abstract
An original 3-phase reluctance machine is fed by a current source inverter which is often used with induction motors. The choice of the association is discussed according to the natural or forced commutation of thyristors. Finally, experimental results are presented with the succession of different conducting phases occurring in the invertor.


Résumé
Une machine à réluctance variable triphasée, de type original, est entraînée par un convertisseur à thyristors habituellement utilisé avec les moteurs asynchrones. Le choix de cette association est discuté du point de vue de la commutation, naturelle ou forcée, des thyristors. Les résultats expérimentaux sont enfin présentés en détaillant les différentes séquences de conduction au niveau de l'onduleur.

PACS
8310D - Synchronous machines.

Key words
reluctance motors -- force commutated invertor -- reluctance machine -- current source inverter -- forced communication -- thyristors -- 150 kW -- 200 Hz