La fonctionnalité Article cité par… liste les citations d'un article. Ces citations proviennent de la base de données des articles de EDP Sciences, ainsi que des bases de données d'autres éditeurs participant au programme CrossRef Cited-by Linking Program. Vous pouvez définir une alerte courriel pour être prévenu de la parution d'un nouvel article citant " cet article (voir sur la page du résumé de l'article le menu à droite).
On the analysis of H in thin layers of Pt electroless contacts using elastic recoil detection technique
M. Roumie, F. Lmai, K. Zahraman, et al. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 341 44 (2014) https://doi.org/10.1016/j.nimb.2014.06.035
Narrow-gap II–VI Compounds for Optoelectronic and Electromagnetic Applications
Cadmium telluride small probes for gamma-ray spectrometry
M Hage-Ali, J.M Koebel, R Régal, et al. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 380(1-2) 427 (1996) https://doi.org/10.1016/S0168-9002(96)00317-8
Cadmium telluride (CdTe) miniature probes for nuclear fuel gamma-ray spectrometry
M. Hage-Ali, J.M. Koebel, P. Siffert, V. Prat and H. Simon Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 369(2-3) 622 (1996) https://doi.org/10.1016/S0168-9002(96)80064-7
Local polarization phenomena in In-doped CdTe X-ray detector arrays
Semiconductors for Room Temperature Nuclear Detector Applications
R.B. James, T.E. Schlesinger, Jim Lund and Michael Schieber Semiconductors and Semimetals, Semiconductors for Room Temperature Nuclear Detector Applications 43 335 (1995) https://doi.org/10.1016/S0080-8784(08)62748-9
Semiconductors for Room Temperature Nuclear Detector Applications
Makram Hage-Ali and Paul Siffert Semiconductors and Semimetals, Semiconductors for Room Temperature Nuclear Detector Applications 43 291 (1995) https://doi.org/10.1016/S0080-8784(08)62747-7
Current state-of-the-art applications utilizing CdTe detectors
Y. Eisen Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 322(3) 596 (1992) https://doi.org/10.1016/0168-9002(92)91238-5
Effect of hydrogen on high resitivity p-type CdTe
S. Mergui, M. Hage-Ali, J.M. Koebel and P. Siffert Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 322(3) 381 (1992) https://doi.org/10.1016/0168-9002(92)91202-K
Development of two new M-π-n CdTe sensors
Michael R. Squillante, Gerald Entine, Edwin Frederick, Leonard Cirignano and Thomas Hazlett Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 283(2) 323 (1989) https://doi.org/10.1016/0168-9002(89)91379-X
Radiation induced polarization in CdTe detectors
D. Vartsky, M. Goldberg, Y. Eisen, et al. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 263(2-3) 457 (1988) https://doi.org/10.1016/0168-9002(88)90986-2
Some new developments in the field of high atomic number materials
Marc Cuzin Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 253(3) 407 (1987) https://doi.org/10.1016/0168-9002(87)90524-9
A review of ohmic and rectifying contacts on cadmium telluride