Numéro |
Rev. Phys. Appl. (Paris)
Volume 4, Numéro 3, septembre 1969
|
|
---|---|---|
Page(s) | 341 - 343 | |
DOI | https://doi.org/10.1051/rphysap:0196900403034100 |
DOI: 10.1051/rphysap:0196900403034100
Mesure des temps de relaxation spin-réseau du rubis avec des structures maser en transmission
J.C. JezequelC.N.E.T., Centre de Recherches de Lannion (22) )
Abstract
We describe an apparatus for spin-lattice relaxation time measurements with ruby transmission type masers. The basic unit of the equipment derived from the one described by Bowers and Mims, is a microwave bridge with two magic tees. Measurements have been carried out with a two port cavity maser and a travelling wave maser. The observation of relaxation process is done at a frequency of about 4 GHz, the pump frequency being about 4 GHz or 30 GHz. Some typical results for a two port cavity maser are given.
Résumé
On décrit un processus de mesure des temps de relaxation spin-réseau T1 du rubis, dans des structures maser en transmission. L'élément de base du montage dérivé de celui de Bowers et Mims est un pont constitué de deux tés magiques. Le dispositif a été utilisé avec un maser à une cavité en transmission et un maser à ondes progressives, la fréquence d'interrogation étant voisine de 4 GHz, la fréquence de saturation étant voisine de 4 GHz ou de 30 GHz. Quelques résultats expérimentaux avec un maser à une cavité en transmission illustrent la méthode.
0757 - Infrared, submillimeter wave, microwave and radiowave instruments and equipment.
Key words
Measurement method -- Spin-lattice relaxation -- Relaxation time -- Masers -- Microwave radiation -- Travelling waves -- Travelling wave masers