Numéro
Rev. Phys. Appl. (Paris)
Volume 24, Numéro 7, juillet 1989
Page(s) 741 - 759
DOI https://doi.org/10.1051/rphysap:01989002407074100
Rev. Phys. Appl. (Paris) 24, 741-759 (1989)
DOI: 10.1051/rphysap:01989002407074100

Méthode analytique de conduction inverse appliquée à la mesure du coefficient de transfert local sur un cylindre en convection forcée

D. Maillet et A. Degiovanni

Laboratoire LEMTA-CNRS U.A. 875, Ecole des Mines, Parc de Saurupt, 54000 Nancy, France


Abstract
Direct methods of surface heat-transfer coefficient measurement present specific limitations. An inverse method, based on an analytical heat-conduction model for a cylindrical pipe is developped. Calculation of the surface heat-transfer coefficient profile only requires temperature measurements inside the cylinder. Experiments have been made. The results which are presented seem to be coherent with those of other authors.


Résumé
Les méthodes directes de mesure du coefficient local de transfert de chaleur sur une paroi présentent des limitations intrinsèques. Une méthode inverse, basée sur un modèle analytique de conduction de la chaleur dans un tube cylindrique, est développée. Elle permet, à partir des seules mesures de température à l'intérieur du cylindre, de remonter au profil de coefficient de transfert en surface. Des résultats expérimentaux, cohérents avec ceux de la littérature, sont présentés.

PACS
4725Q - Convection and heat transfer.
4760 - Flows in ducts, channels, and conduits.
4410 - Heat conduction models, phenomenological description.

Key words
heat conduction -- inverse problems -- pipe flow -- cylinder -- cross flow -- inverse method -- analytical heat conduction model -- cylindrical pipe -- surface heat transfer coefficient -- temperature measurements